  • 1
  • 2
  • 3

Place of Origin : China

Brand Name : TRT or OEM

Certification : CE,CB

Model Number : TRT-30LTASHP-HC

MOQ : 1

Price : Negotiable

Packaging Details : plywood

Delivery Time : 15-20 days

Payment Terms : TT

Supply Ability : 1000 PCS a month

Contact Now

      TRT-30LTASHP-HC22 TRT-30LTASHP-HC38 TRT-50LTASHP-HC22
Metel plate Galvanized steel/Spray/Gray/White (304 Stainless Steel is optional)
Body size(L*W*H) 830*420*1160 830*420*1160 1230*430*1300
Compressor Copeland ZW30KSE*1 Copeland ZW34KSE*1 Copeland ZW52KSE*1
Refrigerant R407C/1.8kg*1 R407C/1.8kg*1 R407C/2.1kg*1
Power Supply 220V/50Hz 380V/50Hz 220V/50Hz
Condenser Tube in Tube Tube in Tube Tube in Tube
φ42*3M φ42*3M φ42*5M
Evaporator 300-785-250*600 300-785-250*600 320-700*1200
U-2/φ9.52/25UPipe U-2/φ9.52/25UPipe L-2/φ9.52/25UPipe
Plate heat exchanger(Economizer) B3-16-16 B3-16-16 B3-16-18
Liquid Storage Tank 145VW-B04-A*1 145VW-B04-A*1 145VW-B04-A*1
Gas-liquid separator LF8W5A-03A*1 LF8W5A-03A*1 KFR120WLG-A*1
Four-way Valve SHF-11-45D1*1 SHF-11-45D1*1 SHF-20A-46*1
Thermostatic expansion valve 1RT+3RT 1RT+3RT 2RT+5RT
AC Contactor (220V-25A)*1 (220V-18A)*1 (220V-32A)*1
Motor/ Fan Blade 90W*1/φ490*1 90W*1/φ490*1 90W*2/φ490*2
Control Single System Single System Single System
Low Pressure Switch 0.1/0.15MPa 0.1/0.15MPa 0.1/0.15MPa
High Pressure Switch 2.4/3.0MPa 2.4/3.0MPa 2.4/3.0MPa
Power Line 3*2.5mm2 3*2.5mm2+2*1.5mm2 3*6mm2+2*2.5mm2
Packing Polywood packing Polywood packing Polywood packing
Cooling 35℃ Cooling Capacity(kW) 6.65 7.23 12.3
Input power(kW) 2.32 2.59 4.25
Rated Current(A) 11 6 18
EER 2.87 2.79 2.89
Rated inlet/outlet water Temp(℃) 12/7 12/7 12/7
Water Flow(m3/H) 1.43 1.55 2.64
Heating 7℃ Heating Capacity(kW) 8.43 9.4 16.8
Input Power(kW) 2.32 2.59 4.25
Rated Current(A) 11 6 18
COP 3.63 3.63 3.95
Rated inlet/outlet water Temp(℃) 40/45 40/45 40/45
Water Flow(m3/H) 1.81 2.02 3.61
-10℃ Heating Capacity(kW) 5.38 6.05 10.6
Input Power(kW) 2.25 2.55 4.2
COP 2.39 2.37 2.52
-20℃ Heating Capacity(kW) 4.75 5.27 9.2
Input Power(kW) 2.2 2.48 4.1
COP 2.16 2.13 2.24
Waterproof Grade IPX4 IPX4 IPX4
Anti-electric shock Rate I I I
Noise(dB(A)) ≤55 ≤55 ≤58
Net Weight/ Gross Weight(kg) 106/114 106/114 150/160
Pipe size/ Inner diameter(mm) DN25 DN25 DN25

8KW,9 KW,16KW EVI low temperature air source heat pump for cooling and heating

Description

  1. Environmental friendly and safe

Electric parts and water system is completely cut off, ensuring security water use, no pollution to the atmosphere and free of greenhouse effect and it is the safest water heater

  1. Wide climatic zone adaptability

Our heat pumps with special designing possess better climatic adaptability, can work from -25℃ to 43℃.

  1. Energy-saving

Heat pump water heater is a high efficient transferring heating equipment which is driven by electricity. The operating cost is only 1/4 of electric water heater, 1/3 of gas water heater.

  1. Automatic intelligent control system

Adopting intelligent computerized automatic control system, no manual cost, easy to operate, convenient, make heat pump work safely and reliably.

Control panel with modularized unit design can control more flexible heat pumps packs, with user-friendly operating system interface, easy to operate..

  1. Advanced testing methods

Adopting world-class Enthalpy potential laboratory to test heat pumps, except basic testing items, we also test heat pump in the ambient of temperature of -30℃ to test our heat pump performance.

  1. Widely used

Heat pump is applied to hot water for household and commercial use like families, schools, hospitals, shower center, swimming pools, etc. and industrial use like electroplating, drying, etc.

Competitive Advantage:

  1. EVI technology:

Adopting the most advanced low temp Enhanced Vapors Injection compressor technology which can help heat pump work steadily even at temperature of -25℃.

  1. Wide range of temperature:

EVI heat pump can work from -25℃.to 43℃. Widely used in different environment.

3. Higher heating capacity:

Using enlarging evaporator extracting more heat energy from air will increase COP.

  1. Automatic start-up anti-freezing protection

When the ambient is below zero degree, the unit is in standby mode more than 30 minutes, Automatic anti-freezing device will be started up so that the unit will be protecting in lower temperature.

8KW,9 KW,16KW EVI low temperature air source heat pump for cooling and heating


 8KW,9 KW,16KW EVI low temperature air source heat pump for cooling and heating Manufactures

8KW,9 KW,16KW EVI low temperature air source heat pump for cooling and heating Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Guangdong TRT Energy Saving Equipment Co.,LTD
*Subject:
*Message:
Characters Remaining: (0/3000)